 | Was: $ 29.95 On Sale $ 24.50 Shipping: $ 10.95 Your Cost: $ 35.45 SUPERGREEN IS A PENETRATING CONCRETE SURFACE CLEANER AND RENOVATOR THAT QUICKLY DISSOLVES LIME DEPOSITS, SCALE, RUST, MORTAR, ALGAE AND DIRT STAINS FROM CONCRETE INTERIOR OR EXTERIOR WITHOUT THE DANGERS OF RAW MURIATIC ACID. Printable Version | Enviromental ImpactSuperGreen contains no hydrofluoric acid, ozone depleting solvents or heavy toxic metals or chromates. ApplicationsSuperGreen is the safe replacement for muriatic acid to clean concrete, tile, brick, and even glass and aluminum frames to remove lime, scale, excess mortar, algae and stains prior to sealing or acid staining of the concrete. This product helps to prepare concrete to insure reaction and penetration of our acid stains. Also insures better bonding of spray textures and overlay applications. Benefits The safe replacement for muriatic acid: SuperGreen produces no harsh or irritating fumes even in interior areas where raw muriatic acid produces chocking and corrosive fumes.  Will not burn concrete: SuperGreen can be used at full strength on difficult stains and will not degrade the concrete surface or interfere with acid staining of the concrete.  Fast Action: SuperGreen works fast and efficiently with deep penetrating action that lifts off stains with minimum of effort and no excess product wasted. ý Economical: Because it is a strong, surfaceactive penetrant rather than a harsh strong acid, SuperGreen does the job faster, with less labor and less product. You save all around.  Will not attack most metals: Most metal encountered on the job will be either steel or aluminum. SuperGreen is highly inhibited against attack on these metals. It will brighten copper and brass, but will not corrode them if washed off. It should not be used on magnesium, galvanized metal or stainless steel. Test plastic laminates How To Use Polyethylene or similar plastic sprayers and buckets are recommended for application. Do not use Nylon brushes. For safety, always use goggles and protective gloves.  Depending on the type of stain or soil SuperGreen may be used full strength or diluted up to 1:3 with water.  Apply SuperGreen by brush, spray or dipping. For spray, use a very coarse spray pattern to avoid inhaling the mist and causing over spray.  Allow it to soak for several minutes. Agitate heavy soil or stains with a stiff broom, then rinse thoroughly with water. Repeat application may be required on some stains. Properties Type: Penetrating acidic detergent renovator. Colors: Green Odor: Pleasant Toxicity: Low. Do not take internally VOC’s: Low Flammability: Non-flammable Composition: Biodegradable surfactants, inhibitors and acidic boosters Material Safety Data for Super Green Part A | SUPPLIER IDENTIFICATION LunaCrete® 1111 H. Enterprise Court Holly Hill, FL 32117 386-252-4243
Emergency Phone Number: 1-800-535-5053
Super Green may be used to comply with OSHA's Hazard Communication Standard (HCS), 29 CFR 1910, 1200. Standard must be consulted for specific requirements.
The precise composition of this product is proprietary information. A more complete disclosure can be provided in the event of a medical emergency.
NFPA National FireProtection Association | TOXICITY [HEALTH] | 2 | FIRE | 0 | REACTIVITY | 2 | SPECIAL | B |
NFPA Number Codes 4 - Extreme 3 - High 2 - Moderate 1 - Slight 0 - Insignificant HMIS Hazardous Materials Identification System | HEALTH | 2 | FIRE | 0 | REACTIVITY | 2 | PROTECTION | |
HMIS Number Codes 4 - Severe 3 - Serious 2 - Moderate 1 - Slight 0 - Minimal
HMIS Protective Equipment Codes A - safety glasses B - safety glasses and gloves C - safety glasses, gloves and an apron D - face shield, gloves and an apron E - safety glasses, gloves and a dust respirator F - safety glasses, gloves, apron and a dust respirator G - safety glasses, a vapor respirator H - splash goggles, gloves, apron and a vapor respirator I - safety glasses, gloves and a dust/vapor respirator J - splash goggles, gloves, apron and a dust/vapor respirator K - airline hood or mask, gloves, full suit and boots
The Material Safety Data provided on this website is correct to the best of our knowledge, information and belief at the date of its publication. The information given is designed only as a guide for safe handling, use, processing, storage, transportation, disposal and release and is not to be considered as a warranty or quality specification. The information relates only to the specific material designated and may not be valid for such material used in combination with any other material or in any process, unless specified in the text.
Product will perform as indicated by product specification sheet. Any adulteration will negate LunaCrete liability. | FOR 1 GALLON
Evaluation for OSHA HCS: Hazardous
GENERAL INFORMATION Chemical Family: Mixture
HAZARDOUS INGREDIENTS
Principal Hazardous Components Hydrochloric Acid (7647-01-0) Threshold Limit Value (Units) 5 ppm (ceiling) PHYSICAL DATA Boiling Point: 212 F Specific Gravity (H20=1) 1.045 Vapor Pressure (mm Hg) NE Percent Volatile By Volume >90 Vapor Density (Air=1) >1 Evaporation Rate (H2O=1) ~1 Solubility in Water Complete pH <1 Appearance & Odor: Blue liquid with pleasant odor
FIRE & EXPLOSION HAZARD DATA
Flash Point (Test Method) None Flammable Limits LEL NA UEL NA Extinguishing Media: Same as for surrounding materials Special Fire Fighting Procedures: Wear NIOSH/MSHA approved breathing apparatus for acid fumes when this product is involved in a fire. Unusual Fire & Explosion Hazards: Product exposed to high heat may generate toxic and corrosive acid vapors.
HEALTH HAZARD DATA
OSHA Permissible Exposure Limit HCl – 5 ppm Ceiling ACGIH Threshold Limit Value HCl = 5 ppm Carcinogen - NTP Program NO Carcinogen – IARC Program NO Symptoms of Over Exposure: INHALATION: Sore throat, irritation, coughing, shortness of breath. INGESTION: Abdominal pain, diarrhea, stomach up set. EYES: Redness, irritation, blurred vision, pain. SKIN: Irritation. Medical Conditions Aggravated by Exposure: Respiratory problems Primary Route(s) of Entry: Ingestion, Skin contact. Emergency First Aid: INGESTION: DO NOT INDCUCE VOMITING. Rinse mouth and drink 1-2 glasses of water. Get Immediate Medical Help. INHALATION: Remove to fresh air, rest upright. If discomfort persists, Get Medical Help. EYE CONTACT: Flush eyes immediately with water for 20 minutes, lifting both eyelids. Get Medical Help. SKIN CONTACT: Remove contaminated clothing. Flush skin with water and soap thoroughly. Wash clothing before reuse.
REACTIVITY DATA
Stability Stable Conditions to Avoid: Extreme heat Incompatibility Materials to Avoid: Alkaline products, caustic, bleach. Hazardous Polymerization: No Conditions to Avoid: NA Hazardous Decomposition Products: HCl, organic vapors
ENVIRONMENTAL PROTECTION PROCEDURES
Spill Response: Wear protective equipment during clean up. Confine spill and reclaim as much product as possible by mopping or collecting on absorbent material. Collect in sealable containers. Sprinkle residue with soda ash or limestone to neutralize and flush neutral residue to drain. Waste Disposal Method: Seal containers and dispose of at an approved waste disposal facility, or neutralize reclaimed liquid to a pH of 7-8 and release to drain as local regulations permit.
SPECIAL PROTECTION INFORMATION
Eye Protection: Goggles Skin Protection: Rubber or plastic gloves Respiratory Protection (Specific Type) OSHA approved respirator with acid cartridge if applying in confined areas with poor ventilation. Ventilation Recommended General Mechanical Other Protection: NA Hygienic Practices in Handling & Storage: Wash hands after handling. Do not contaminate food or feed stuff. Precautions for Repair & Maintenance of Contaminated Equipment: NA Other Precautions: Store in original container, below 120 F. Read all label precautions before using |
For additional information contact: LunaCrete® 1111 H. Enterprise Court Holly Hill, FL 32117 (866) 386-9122 - Toll Free Material Safety Data for Super Green Part B | SUPPLIER IDENTIFICATION LunaCrete® 1111 H. Enterprise Court Holly Hill, FL 32117 386-252-4243
Emergency Phone Number: 1-800-535-5053
Super Green may be used to comply with OSHA's Hazard Communication Standard (HCS), 29 CFR 1910, 1200. Standard must be consulted for specific requirements.
The precise composition of this product is proprietary information. A more complete disclosure can be provided in the event of a medical emergency.
NFPA National FireProtection Association | TOXICITY [HEALTH] | 2 | FIRE | 0 | REACTIVITY | 2 | SPECIAL | B |
NFPA Number Codes 4 - Extreme 3 - High 2 - Moderate 1 - Slight 0 - Insignificant HMIS Hazardous Materials Identification System | HEALTH | 2 | FIRE | 0 | REACTIVITY | 2 | PROTECTION | |
HMIS Number Codes 4 - Severe 3 - Serious 2 - Moderate 1 - Slight 0 - Minimal
HMIS Protective Equipment Codes A - safety glasses B - safety glasses and gloves C - safety glasses, gloves and an apron D - face shield, gloves and an apron E - safety glasses, gloves and a dust respirator F - safety glasses, gloves, apron and a dust respirator G - safety glasses, a vapor respirator H - splash goggles, gloves, apron and a vapor respirator I - safety glasses, gloves and a dust/vapor respirator J - splash goggles, gloves, apron and a dust/vapor respirator K - airline hood or mask, gloves, full suit and boots
The Material Safety Data provided on this website is correct to the best of our knowledge, information and belief at the date of its publication. The information given is designed only as a guide for safe handling, use, processing, storage, transportation, disposal and release and is not to be considered as a warranty or quality specification. The information relates only to the specific material designated and may not be valid for such material used in combination with any other material or in any process, unless specified in the text.
Product will perform as indicated by product specification sheet. Any adulteration will negate LunaCrete liability. | FOR 5 GALLONS
Evaluation for OSHA HCS: Hazardous
ENERAL INFORMATION Chemical Family : MIXTURE
HAZARDOUS INGREDIENTS
Principal Hazardous Components Threshold Limit Value (Units) Hydrochloric Acid (7647-01-0) 5 ppm (ceiling) PHYSICAL DATA
Boiling Point 212 F Specific Gravity (H20=1) 1.045 Vapor Pressure (mm Hg) NE Percent Volatile By Volume >90 Vapor Density (Air=1) >1 Evaporation Rate (H2O=1) ~1 Solubility in Water Complete . pH <1 Appearance & Odor: Blue liquid with pleasant odor
FIRE & EXPLOSION HAZARD DATA
Flash Point (Test Method) None Flammable Limits LEL NA UEL NA Extinguishing Media: Same as for surrounding materials Special Fire Fighting Procedures: Wear NIOSH/MSHA approved breathing apparatus for acid fumes when this product is involved in a fire. Unusual Fire & Explosion Hazards: Product exposed to high heat may generate toxic and corrosive acid vapors.
HEALTH HAZARD DATA
OSHA Permissible Exposure Limit HCl – 5 ppm Ceiling ACGIH Threshold Limit Value HCl = 5 ppm Carcinogen NTP Program NO IARC Program NO Symptoms of Over Exposure: INHALATION: Sore throat, irritation, coughing, shortness of breath. IIGESTION: Abdominal pain, diarrhea, stomach up set. EYES: Redness, irritation, blurred vision, pain. SKIN: Irritation. Medical Conditions Aggravated by Exposure: Respiratory problems Primary Route(s) of Entry: Ingestion, Skin contact. Emergency First Aid: INGESTION: DO NOT INDUCE VOMITING. Rinse mouth and drink 1-2 glasses of water. Get Immediate Medical Help. INHALATION: Remove to fresh air, rest upright. If discomfort persists, Get Medical Help. EYE CONTACT: flush eyes immediately with water for 20 minutes, lifting both eyelids. Get Medical Help. SKIN CONTACT: Remove contaminated clothing. Flush skin with water and soap thoroughly. Wash clothing before reuse.
REACTIVITY DATA
Stability Stable Conditions to Avoid: Extreme heat Incompatibility Materials to Avoid: Alkaline products, caustic, bleach. Hazardous Polymerization No Conditions to Avoid: NA Hazardous Decomposition Products: HCl, organic vapors
ENVIRONMENTAL PROTECTION PROCEDURES
Spill Response: Wear protective equipment during clean up. Confine spill and reclaim as much product as possible by mopping or collecting on absorbant. Material. Collect in sealable containers. Sprinkle residue with soda ash or limestone to neutralize and flush neutral residue to drain. Waste Disposal Method: Seal containers and dispose of at an approved waste disposal facility, or neutralize reclaimed liquid to a pH of 7-8 and release to drain as local regulations permit.
SPECIAL PROTECTION INFORMATION
Eye Protection: Goggles Skin Protection: Rubber or plastic gloves Respiratory Protection (Specific Type) OSHA approved respirator with acid cartridge if applying in confined areas with poor ventilation.
Ventilation Recommended General Mechanical Other Protection: NA Hygienic Practices in Handling & Storage: Wash hands after handling. Do not contaminate food or feed stuff. Precautions for Repair & Maintenance of Contaminated Equipment: NA Other Precautions: Store in original container, below 120 F. Read all label precautions before using.
TRANSPORT INFORMATION Identification Number UN 1789 (ORM-D Inner packages <5L) Proper shipping name Hydrochloric acid Class/Division 8 Packaging Group III |
For additional information contact: LunaCrete® 1111 H. Enterprise Court Holly Hill, FL 32117 (866) 386-9122 - Toll Free |  | If you have already purchased access to an online video, |
|
|